Understanding Glycol in Process Cooling and HVAC: Properties, Applications, and Essential Maintenance

WHAT IS GLYCOL?


Glycol is a type of chemical compound characterized by having two hydroxyl (OH)groups attached to different carbon atoms. The most common types used in HVAC and industrial applications are:

propylene glycol molecularstructure

Ethylene glycol (C2H6O2): A viscous liquid with a sweet odor and typically colored for identification purposes. It has excellent heat transfer properties and is commonly used as an antifreeze but is toxic if ingested.


Propylene glycol (C3H8O2): A less toxic alternative to ethylene glycol with similar properties. It's considered safer for applications where there might be human contact or environmental concerns. "Food-grade" propylene glycol refers to a high-purity version that meets FDA requirements for incidental food contact, making it the preferred choice in applications where safety is paramount.

In HVAC and process cooling systems, glycol is typically mixed with water to create a solution that:


•    Lowers the freezing point of water (preventing pipe bursts in cold conditions)
•    Raises the boiling point (allowing for higher temperature operation)
•    Provides corrosion inhibition when properly formulated with additives
•    Maintains effective heat transfer properties

​

The concentration of glycol in the water mixture determines the freezing point protection, with higher concentrations providing protection at lower temperatures.​

COMMON APPLICATIONS


Glycol is commonly used in:

​

•    Chilled water systems
•    Hot water systems
•    Heat recovery loops
•    Thermal energy storage

​

Its ability to lower water's freeze point allows HVAC and process cooling systems to operate efficiently in various climates, significantly reducing the risk of freezing.

​

DESIGN CONSIDERATIONS


HVAC and process cooling design engineers must account for several factors when working with glycol systems:

chiller plant
  • Temperature Range: Consider both freeze point and boiling point temperature ranges for system operation.

  • Material Compatibility: Ensure long-term compatibility with pumps, piping, and heat exchangers.

  • Viscosity Management: Account for glycol's increased viscosity, measured in centipoise (cP), particularly in pump selection. This is especially important at lower temperatures where viscosity increases significantly.

  • Heat Transfer Optimization: Design for appropriate flow rates to optimize heat transfer, especially in heat exchangers.

  • Piping Configuration: Minimize pressure drops, avoid dead spots where glycol can stagnate, and ensure proper insulation R-value to reduce heat loss.

  • Emergency Planning: Consider emergency power for circulating pumps or incorporate freeze protection pumps where applicable.

​

INSTALLATION AND COMMISSIONING


Chilled water and hot water systems typically undergo several important steps during installation and commissioning:


•    Pressure test chilled water and hot water systems
•    Clean systems with solutions like trisodium phosphate (TSP)
•    Add glycol with rust inhibitor mixed to a specific freeze protection point
•    Circulate for a designated period
•    Verify the specified freeze point using a digital refractometer


MAINTENANCE REQUIREMENTS


All glycol systems require specific preventive maintenance (PM):

​

•    Concentration Monitoring: Glycol concentrations typically decrease over time to levels that provide inadequate freeze protection. While the primary cause is often maintenance activities where portions of the system are drained and refilled with water only (without adjusting the makeup system's glycol-water mixture), some glycol can also be lost through small leaks, venting, or chemical breakdown over extended periods. If the glycol concentration becomes too diluted, the system loses its freeze protection capabilities, putting pipes and equipment at risk during cold conditions.

•    Regular Testing: Regular testing of glycol freeze protection points is essential for system reliability. Using digital refractometers or other appropriate testing equipment, maintenance personnel should verify that the glycol solution maintains the proper freeze point specified in the system design. Seasonal testing is particularly important, especially before cold weather periods. Besides freeze protection, regular testing can also reveal issues with pH levels and inhibitor concentrations that could lead to corrosion within the system. Establishing a consistent testing schedule as part of the preventive maintenance program helps prevent system damage and extends equipment life.

​

​

•    Regular Testing: Regular testing of glycol freeze protection points is essential for system reliability. Using digital refractometers or other appropriate testing equipment, maintenance personnel should verify that the glycol solution maintains the proper freeze point specified in the system design. Seasonal testing is particularly important, especially before cold weather periods. Besides freeze protection, regular testing can also reveal issues with pH levels and inhibitor concentrations that could lead to corrosion within the system. Establishing a consistent testing schedule as part of the preventive maintenance program helps prevent system damage and extends equipment life.

​

•    Flow Verification: Proper flow rates are essential for optimal heat transfer in glycol systems. Regular verification using circuit balancing valves or an ultrasonic flow meter ensures the system is operating at design specifications. Inadequate flow can lead to poor heat transfer, while excessive flow can cause erosion and unnecessary pump energy consumption. Periodic flow testing also helps identify potential blockages, air entrapment, or pump performance issues before they develop into larger problems.


•    Performance Checks: Thermal imaging provides valuable insights into the performance of heat exchange equipment. By scanning coils, heat exchangers, and piping systems, maintenance personnel can identify uneven heat distribution, blocked passages, air pockets, or fouling that might not be apparent through other testing methods. These proactive inspections can identify inefficiencies before they impact overall system performance, helping maintain optimal energy efficiency and extending equipment life.


THE BOTTOM LINE


Glycol systems are essential for reliable HVAC operation in climates where freezing is a concern, but they require ongoing attention to maintain their effectiveness. The key to long-term success lies in establishing a comprehensive maintenance program that includes regular concentration testing, flow verification, and performance monitoring.


By staying proactive with these maintenance requirements, facility managers can ensure their glycol systems provide years of reliable freeze protection while maintaining optimal energy efficiency. A modest investment in regular glycol testing and maintenance far outweighs the potential costs of system damage from inadequate freeze protection or poor heat transfer performance.

​

​